Smarter Salt‑to‑Acid/Base Conversion with EDBM/BPED
Junction management, purity targets, and energy balance optimization for acid/base generation and recovery
Who it’s for: Sites converting salts to acid/base (e.g., NaCl→HCl/NaOH) or recovering acids/bases from process liquors.
Deliverables:
Junction management (gas evolution risk, CO₂ ingress, nitrogen blanketing strategy)
Acid/base purity targets and recycle schemes
Cell pair selection, chemical balances, and utility loads
Fouling/playbook tied to ΔV/cell-pair
Typical engagement: 3–8 weeks including modeling or piloting support, remote + on-site as needed.
FAQ:
What purity can we hit without polishing? We’ll map purity vs. energy and suggest polishing steps if needed.
Is nitrogen blanketing worth it? We quantify ΔV and yield impacts before capex.